Part Number Hot Search : 
FRF1005 B105K UESP08D SMA12 20150 JANSR2 K2299 APW7120A
Product Description
Full Text Search
 

To Download FIREFLY-TX-IPKIT Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  viper remote control systems viper remote control systems viper remote control systems viper remote control systems ds viper-2 ?2009 reg no 277 4001, lewes, england. page 1 applications applications applications applications ? general purpose remote switching ? garage doors ? electric gates, shutters ? all known lighting types (led, fluorescent, halogen , tungsten, xenon; basically all lighting types). ? access control ? 433mhz fm technology ? 1 C 4 channels each 1000w rated ? upto 150metres range ? 12-30vdc / 230vac supply ? waterproof (ip68) ? high security rf protocol ? 4 relays 5a @ 230vac ? outputs momentary or latching ? any switch map to any relay output ? systems supplied ready to go ? emc / fcc compliant for europe / usa description description description description housed in a rugged ip68 weatherproof enclosure, the viper system is ideally suited to any outside remote switch requirement. each receiver has 4 relays, using the easy-learn process each relay can be controlled from any switch on any transmitter. installation is by screw terminals to the power sup ply, and the output relay contacts. the output relays are activated by the button press on the transmitter encoder.
viper remote control systems viper remote control systems viper remote control systems viper remote control systems ds viper-2 ?2009 reg no 277 4001, lewes, england. page 2 systems part numbers operating from 12-30vdc systems operating from 230vac (see ds-vipermains) ** range stated is optimum, direct line of sight. in w orst conditions this can be reduced by over 50% part number part number part number part number description description description description firefly-tx1 transmitter 1 switch firefly-tx2 transmitter 2 switch firefly-tx4 transmitter 4 switch firefly -tx-ipkit o ring, seals transmitter to ip68 firefly-tx8 transmitter 8 switch firefly-tx16 transmitter 16 switch (8sw + shift key) additional transmitters transmitters ship with; transmitters ship with; transmitters ship with; transmitters ship with; wall mounting cradle, and lanyard part number description receiver power supply range** (metres) viper-s1 system 1 channel 12-30vdc 150 viper-s2 system 2 channel 12-30vdc 150 viper-s4 system 4 channel 12-30vdc 150 part number description receiver power supply range** (metres) viper-s1m system 1 channel 230vac 150 viper-s2m system 2 channel 230vac 150 custom version to create a custom version requires just a sticker! please contact sales for further info.
viper remote control systems viper remote control systems viper remote control systems viper remote control systems ds viper-2 ?2009 reg no 277 4001, lewes, england. page 3 installation installation installation installation below is a simple example showing one possible way to wire a relay in order to give switched power to an external load: when the relay is energised the com connects to no and power is applied to the load. data outputs data outputs data outputs data outputs each output relay provides an isolated switch. conne ctions are common (com), normally open (no) and normally closed (nc). com no nc relay connections when transmitter not operating com no nc relay connections when transmitter operating r f solutions ltd., r f solutions ltd., r f solutions ltd., r f solutions ltd., unit 21, cliffe industrial estate, unit 21, cliffe industrial estate, unit 21, cliffe industrial estate, unit 21, cliffe industrial estate, lewes, e. sussex. bn8 6jl. england. lewes, e. sussex. bn8 6jl. england. lewes, e. sussex. bn8 6jl. england. lewes, e. sussex. bn8 6jl. england. email : email : email : email : sales@rfsolutions.co.uk sales@rfsolutions.co.uk sales@rfsolutions.co.uk sales@rfsolutions.co.uk http://www.rfsolutions.co.uk http://www.rfsolutions.co.uk http://www.rfsolutions.co.uk http://www.rfsolutions.co.uk tel: +44 (0)1273 898 000 tel: +44 (0)1273 898 000 tel: +44 (0)1273 898 000 tel: +44 (0)1273 898 000 fax: +44 (0)1273 480 661 fax: +44 (0)1273 480 661 fax: +44 (0)1273 480 661 fax: +44 (0)1273 480 661
viper remote control systems viper remote control systems viper remote control systems viper remote control systems ds viper-2 ?2009 reg no 277 4001, lewes, england. page 4 pairing a transmitter to a receiver pairing a transmitter to a receiver pairing a transmitter to a receiver pairing a transmitter to a receiver each transmitter has a unique identity. each time a t ransmitter switch is operated, it emits a secure rf signal. the receiver can learn this signal and a llocate to any of its outputs. the only limitation is that each receiver has a max imum memory for upto 40 pairings, these can be from the same or any number of transmitters. hint: the same transmitter may be taught to differe nt receivers to create master keys. viper viper viper viper- -- -s1 / viper s1 / viper s1 / viper s1 / viper- -- -s2 / viper s2 / viper s2 / viper s2 / viper- -- -s3 (12 s3 (12 s3 (12 s3 (12- -- -30vdc receivers) 30vdc receivers) 30vdc receivers) 30vdc receivers) to learn a new transmitter switch follow this proce dure to learn a new transmitter switch follow this proce dure to learn a new transmitter switch follow this proce dure to learn a new transmitter switch follow this proce dure any transmitter button can be learnt to one or many of the receiver output relays. each button must be learnt to each relay individuall y by following this procedure: 1. select the receiver output relay to learn to: 2. briefly press the receiver learn switch (s2) onc e 3. the learn led will flash once to indicate output relay 1 is selected 4. after the led stops flashing, press the learn sw itch again to select the next relay channel 5. repeat step 2 until the required output relay is selected. 6. press the button on the transmitter you want to learn to the relay output. 7. the learn led will then illuminate, press the sam e transmitter button again. 8. the learn led will then flash to indicate learnin g is complete. 9. the transmitter button will now operate the rela y. erasing receivers memory erasing receivers memory erasing receivers memory erasing receivers memory 1. press and hold the receiver learn switch for app rox 10 seconds. 2. when the learn led turns off all memory is erased note: note: note: note: you cannot erase individual tx encoders configuring receiver outputs configuring receiver outputs configuring receiver outputs configuring receiver outputs the jumper links configure the outputs to be moment ary or latching. the jumper links are made / removed by the small li nk cap placed over the pin header. (the configuration shown in the picture above rep resents the third row of the table) link positions link positions link positions link positions relay outputs relay outputs relay outputs relay outputs lk1 lk1 lk1 lk1 lk2 lk2 lk2 lk2 rly 1 rly 1 rly 1 rly 1 rly 2 rly 2 rly 2 rly 2 rly 3 rly 3 rly 3 rly 3 rly 4 rly 4 rly 4 rly 4 closed closed mom mom mom mom closed open mom mom latch latch open closed mom latch latch latch open open latch latch latch latch
viper remote control systems viper remote control systems viper remote control systems viper remote control systems ds viper-2 ?2009 reg no 277 4001, lewes, england. page 5 viper viper viper viper- -- -s1m / viper s2m (230vac powered receivers) s1m / viper s2m (230vac powered receivers) s1m / viper s2m (230vac powered receivers) s1m / viper s2m (230vac powered receivers) please note: please note: please note: please note: during learn and erase the relays operate at high sp eed. they should be isolated from sensi- tive equipment during this process. to pair a transmitter button to receiver output rel ay #1 to pair a transmitter button to receiver output rel ay #1 to pair a transmitter button to receiver output rel ay #1 to pair a transmitter button to receiver output rel ay #1 1. apply power the receiver and wait 10secs for the unit to enter normal operation mode. 2. switch the receiver unit off and then on again i n ~1sec intervals four four four four times finally leaving the unit powered. 3. after 5 seconds the receiver emits a single buz z the unit is now in learn mode 5. press the chosen transmitter button. 6. the receiver will acknowledge by sounding the a single buzz 7. press the same transmitter button again, to conf irm ok. the receiver will buz again to confirm. 8. learn process complete. after 10 seconds the uni t will return to normal operation mode. to pair a transmitter button to receiver output rel ay #2 to pair a transmitter button to receiver output rel ay #2 to pair a transmitter button to receiver output rel ay #2 to pair a transmitter button to receiver output rel ay #2 1. apply power the receiver and wait 10secs for the unit to enter normal operation mode. 2. switch the receiver unit off and then on again i n ~1sec intervals six sixsix six times finally leaving the unit powered. 3. after 5 seconds the receiver emits a double buz z the unit is now in learn mode 5. press the chosen transmitter button. 6. the receiver will acknowledge by sounding the a double buzz 7. press the same transmitter button again, to conf irm ok. the receiver will double buzz again to confirm. 8. learn process complete. after 10 seconds the uni t will return to normal operation mode. erasing receivers memory erasing receivers memory erasing receivers memory erasing receivers memory 1. power the receiver unit up and wait 10 seconds f or the unit to enter normal operation mode. 2. switch the unit off and then on again at ~1 seco nd intervals ten ten ten ten times, leaving the unit powered. 3. wait 5 seconds until a clicking sound is heard for a period of 10 seconds. 4. wait 10 seconds for the receiver unit to return to normal mode 5. the unit has now erased all encoder data. note: note: note: note: you cannot erase individual tx encoders configuring receiver outputs configuring receiver outputs configuring receiver outputs configuring receiver outputs the jumper links configure the outputs to be moment ary or latching. the jumper links are made/removed by the small link cap placed over the pin header. lk1 lk1 lk1 lk1 relay #1 relay #1 relay #1 relay #1 lk2 lk2 lk2 lk2 relay #2 relay #2 relay #2 relay #2 open mom open mom closed latch closed latch link positions link positions link positions link positions - -- - relay outputs relay outputs relay outputs relay outputs (the above image shows, rly2 momentary, rly1 latch ed) (the above image shows, rly2 momentary, rly1 latch ed)
viper remote control systems viper remote control systems viper remote control systems viper remote control systems ds viper-2 ?2009 reg no 277 4001, lewes, england. page 6 r f solutions ltd., r f solutions ltd., r f solutions ltd., r f solutions ltd., unit 21, cliffe industrial estate, unit 21, cliffe industrial estate, unit 21, cliffe industrial estate, unit 21, cliffe industrial estate, lewes, e. sussex. bn8 6jl. england. lewes, e. sussex. bn8 6jl. england. lewes, e. sussex. bn8 6jl. england. lewes, e. sussex. bn8 6jl. england. email : email : email : email : sales@rfsolutions.co.uk sales@rfsolutions.co.uk sales@rfsolutions.co.uk sales@rfsolutions.co.uk http://www.rfsolutions.co.uk http://www.rfsolutions.co.uk http://www.rfsolutions.co.uk http://www.rfsolutions.co.uk tel: +44 (0)1273 898 000 tel: +44 (0)1273 898 000 tel: +44 (0)1273 898 000 tel: +44 (0)1273 898 000 fax: +44 (0)1273 480 661 fax: +44 (0)1273 480 661 fax: +44 (0)1273 480 661 fax: +44 (0)1273 480 661 technical specifications technical specifications technical specifications technical specifications transmitters: firefly transmitters: firefly transmitters: firefly transmitters: firefly- -- -txn txn txn txn enclosure rating: standard ipx8 battery type: cr2032 (supplied) dimensions: 90 x 54 x 27 mm changing the battery: remove the six fixing screws, remove battery and replace note polarity receiver decoder receiver decoder receiver decoder receiver decoder enclosure rating ip68 dimensions 130 x 112 x 42 mm (not including anten na) storage temperature: -10 to +70 o celsius. operating temperature: -10 to +50 o celsius. *the relay contacts in this unit are for functional use only and must not be used for isolation purpos es *the relay contacts in this unit are for functional use only and must not be used for isolation purpos es *the relay contacts in this unit are for functional use only and must not be used for isolation purpos es *the relay contacts in this unit are for functional use only and must not be used for isolation purpos es electrical characteristics min typical max units supply voltage 3v v supply current ma frequency: firefly: wideband 432.90 433.920 434.10 mhz rf output power (erp) @ 433 mhz - 3 10 mw electrical characteristics min typical max dimension supply voltage for +12 v 10.5 30 vdc relay rating* (230vac) rly1-4 5 12 a supply current : quiescent all relays operating* 10 140 ma time delay from tx on switch to rx relay opera- tion 100 ms time delay from tx sw relax to rx relay release 300 ms


▲Up To Search▲   

 
Price & Availability of FIREFLY-TX-IPKIT

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X